Product overview

Dry-type transformers

Low- and medium-voltage dry-type transformers for commercial and industrial distribution, with VPI isolation and cast-resin designs.

Cast-resin dry-type transformer

Technical Specifications

Ratings and Options

Low-voltage dry-type

Capacity range
15–2,500 kVA
Primary voltage
110–600 V
Secondary voltage
110–600 V
Winding options
Copper / aluminum, per customer requirements
Phase
Three-phase
Insulation options
Class H / Class R (220°C), by design

Medium-voltage cast-resin

Capacity range
30–5,000 kVA
Primary voltage
11–36 kV
Secondary voltage
100–1,500 V
Winding options
Copper / aluminum, per customer requirements
Insulation class
Class H
Cooling
Natural air

Reference Configurations

225 kVA reference configuration

480 V / 415 V, three-phase ventilated dry-type.

ParameterReference value
Rated capacity225 kVA
Primary / secondary voltage480 / 415 V
Phase / frequencyThree-phase / 60 Hz
Winding connectionDyn1
Winding materialCopper
ConstructionVentilated dry-type
Winding rise / insulation120°C / Class H
HV tap adjustment±2 × 2.5%, five positions
BIL10 kV
Impedance4.5% ±10%
No-load loss390 W
Load loss3,850 W
Efficiency at 35% load, 75°C98.99%
K-factorK4
Sound level48 dB
EnclosureIP23

Reference configurations are illustrative. Final specifications, certification and drawings are confirmed for your project.

Download reference specifications (PDF) ↓

Typical features

  • Dry-type construction without insulating liquid.
  • VPI isolation and cast-resin designs for different voltage classes.
  • Copper / aluminum winding options.

Configuration options

  • Specify kVA, primary and secondary voltages, frequency and winding connections.
  • Select taps, temperature rise, cooling and loss requirements.
  • UL 1561 Listed designs are available in selected low-voltage copper series.
  • UL 1562 Recognized Component designs are available in selected medium-voltage copper series.

Protection & enclosure review

  • Select enclosure, ventilation and indoor or outdoor installation requirements.
  • Coordinate terminal access, clearances and overtemperature protection.
  • Confirm the applicable certification and test documentation for the selected design.

Typical applications

  • Commercial facilities
  • Industrial facilities
  • Data centers
  • Healthcare facilities
  • Equipment voltage conversion