Technical Specifications

Ratings and Options

Capacity range
45–5,000 kVA
Primary voltage options
3.5–6.9 / 11–36 kV
Secondary voltage range
100–1,500 V
Construction
Liquid-filled; loop or radial feed
Frequency
60 Hz; other frequencies by design review
Cooling options
ONAN / KNAN, matched to the insulating fluid
Winding connections
Delta / wye, as specified
Front arrangement
Dead front / live front, by design

Reference Configurations

2,500 kVA reference configuration

FR3-filled, 34.5 kV / 480 V reference design.

ParameterReference value
Rated capacity2,500 kVA
Primary / secondary voltage34.5 kV / 480Y/277 V
Phase / frequencyThree-phase / 60 Hz
Winding connectionDyn1
Winding optionsCopper or aluminum
Cooling / insulating fluidKNAN / FR3
Winding temperature rise65 K
HV tap adjustmentDe-energized; ±2 × 2.5%, five positions
BIL, HV / LV150 / 30 kV
Impedance5.75%
No-load loss2,200 W at 20°C
Load loss14,000 W at 55°C, 100% load
Installation / ambientOutdoor / -25°C to +40°C
Design / test standardsIEEE C57.12.00 / C57.12.10 / C57.12.90

Reference configurations are illustrative. Final specifications, certification and drawings are confirmed for your project.

Download reference specifications (PDF) ↓

Typical features

  • No-load tap changer for voltage adjustment.
  • Oil drain and sampling valves.
  • Pressure-relief valve and pressure/vacuum gauge.
  • Liquid-level indicator and temperature gauge.
  • High- and low-voltage bushings with cable connection provisions.
  • Bayonet-fuse protection and loadbreak switching.

Configuration options

  • Mineral oil or less-flammable vegetable fluid; FR3 may be requested.
  • Radial or loop feed; dead-front or live-front arrangements.
  • 55°C, 65°C, or dual 55/65°C temperature-rise designs.
  • Copper or aluminum windings, depending on the selected series.
  • Stainless-steel cabinet and accessory options.
  • Dual-voltage arrangements and alternative secondary connection layouts.

Protection & enclosure review

  • Coordinate expulsion and current-limiting fuse protection with the utility specification.
  • Specify corrosion protection for coastal, humid or industrial locations.

Typical applications

Three-phase pad-mounted transformers for:

  • Utility distribution
  • Commercial facilities
  • Industrial facilities
  • Renewable energy
  • Energy storage